MeasurementNoise#
- class popo.estimation.MeasurementNoise(voltage_pu=0.002, substation_pq_fraction=0.02, smart_meter_pq_fraction=0.1, line_pq_fraction=0.02, floor_mw=1e-05)#
Bases:
objectStandard deviations of the measurements an estimator is given.
Substation instrumentation at a secondary is typically class 0.5 for both power and voltage. Smart meters are far coarser and enter as pseudo-measurements rather than as measurements, which is why their deviation is an order of magnitude larger.
- Variables:
voltage_pu – Substation voltage deviation, in per unit.
substation_pq_fraction – Substation power deviation, as a fraction of the reading.
smart_meter_pq_fraction – Customer power deviation, as a fraction of the reading.
line_pq_fraction – Deviation of a power-flow sensor on a line, as a fraction of the reading; real instrumentation, like the substation’s.
floor_mw – Absolute floor, so a near-zero reading does not get a near-zero deviation and dominate the solution.
- smart_meter_pq_sigma(reading_mw)#
Deviation for a smart-meter pseudo-measurement.
- Return type: